Megger test procedure for motors pdf merge

So when the individual component test lists are merged, a thoughtful and smart overall test recommendation for transformers emerges. The following sections of the ansineta standard for acceptance testing specifications for. Calibration service since 1982 jm test systems has been providing nist traceable calibrations to our customers. Ieee std 432000 recommends a procedure for measuring insulation resistance of armature. Be sure to follow good safety measures to prevent electrical shock. Megger products help you install, improve efficiency, reduce cost and extend the life of your or your customers electrical assets. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of assets and cable networks at high, medium and low voltage. Figure 2 typical megger test instrument hookup to measure insulation resistance. Regular insulation resistance testing is one of the most cost effective, non destructive methods of identifying ageing in electrical equipment. Motors are susceptible to the gradual failure of their insulation resistance. Electrical test equipment power station to plug megger. We are testing the motors insulation, more specifically between the motor windings and the motor casing. Established in the late 1800s, the company has been designing and making test and measurement instruments that perform electrical measurements for.

It is commonly used in the industry for acceptance testing prior to energizing the cable and for maintenance testing programs. Standard for acceptance testing specifications for. Megger designs and manufactures portable electric test equipment. The motor under test must be powered down and disconnected from all equipment and wiring not included in the test. Isbn 07389785 ss95211 no part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.

Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. The certificates can also be customised to include, for example, the users business logo and contact details. Test record card pack of 20 6111216 black test lead with large alligator clip 6220295 red test lead with large alligator clip 6220586 green test lead with large alligator clip 6220587 set of test leads with fused prods fpk5 v a. The purpose of the guard terminal on insulation testers. In the off position, both the meter and the battery are disconnected from all circuits. The megger brand is already strong and highly respected in the industry, but in these times of digital transformation, megger wishes to further elevate the depth of relation with our customers to truly standout. Where as in electronic type megger battery are used to produce the testing voltage. The unit performs excitation, ratio and polarity test by providing a variable output voltage up to 1600 v ac. Have anyone hear of a hi megger testing residential circuits as part of their home inspection.

If a fraction of current flows, it can be measured by these highly sensitive meters. How to test a threephase motor with a megger hunker. The selector switch connects a dsize dry cell into the circuit when the rotation of a motor or the polarity of a transformer is being checked. How to meg a motor with a megohmeter checking motor condition. To properly test this type of motor, remove the wirenuts joining leads 4 and 7, 5 and 8, and 6 and 9. Insulation resistance testing of low voltage cables in the field. Our products are complemented by bespoke software that records all measurements and data, easing the process of information management. Megger makes electrical test equipment to help you install, improve efficiency and extend the life. The megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. Com reference manual applications guide delta 4000 12 kv insulation diagnostic system zmah02e. The complete guide to electrical insulation testing. The procedure of insulation resistance test or megger test are given below. Once you start to record your readings, you will be able to compare them with the output readings that the device should have based on the manufacturers specifications.

Jul 25, 2018 in hand operated megger electromagnetic induction effect is used to produce the test voltage i. Megger has offered a 10 kv insulation resistance tester since 2001. The purpose of this procedure is to provide instructions for performing insulation resistance megger testing of busses, motor control centers mccs, and distribution panels. In hand operated megger electromagnetic induction effect is used to produce the test voltage i. The megger test is a method of testing making use of an insulation. If you think you have what it takes to help us realise our ambitions, we would love to hear. Low resistance ohmmeters for electricians testers megger. If the resistance of the insulation is high, the pointer of the moving coil deflects towards the infinity, and if it is low, then the pointer indicates zero. This is certainly not a new test, and has been in use for a number of years.

How to test three phase ac motors learning electrical. Call us today for a quote at 8003533411 or send us a message. Find here insulation testing and continuity, power protection, power transformer testing, power cable infrastructure, cable fault location, general electrical test. I have not personally ever used a megger but from what i understand that type of test would be very time consuming or am i missing something. Megger testing of busses, mccs, and distribution panels. Megger 560060 phase and motor rotation test 5060h tequipment. Threephase dualvoltage motor insulation resistance testing. A guide to diagnostic insulation testing above 1 kv euroindex. But the megger provides a much higher voltage rather than the ohm meters typical threevolt test voltage derived from an internal battery. As some transformer tests are better suited as commissioning and diagnostic tests, the reason for testing e. Reverse side of card at right is used to record the test data.

The test voltage selected for this type of test is less than 5 kv, and is applied for up to one minute, or until the measured insulation resistance value stabilizes. An important benefit is that the data entry screens are exactly the same as the printed reports, which greatly simplifies interpretation of the test results. Jm test systems has the megger 560060 motor and phase rotation tester for purchase and for rent. This current usually at an applied voltage of 500 volts or more is measured by the ohmmeter, which has. From megger, these highly accurate, easy to operate instruments measure resistance with resolution as fine as 0. Ieee std 1122004, ieee standard test procedure for. The megger 560060 motor and phase rotation tester permits the electrical contractor or industrial maintenance electrician to permanently connect and tape the terminals of the motor being installed, without having to first energize the motor by a temporary hookup from a power source, if available, to determine motor rotation.

Crank the handle for about a minute, and notice the resistance reading. It will calculate the rated knee point in compliance with ieee c57. Jm test systems is a stocking distributor of megger products. Digital microohmeters and dlros measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Figure 4typical record of insulation resistance of a mill motor.

If you are referring to a megohm meter, it is a test of the insulation properties of such things as electric wiring, motor windings and high power antenna mounts. This standard provides the basic test procedure for evaluating the performance of a. The megger is the instrument uses for measuring the resistance of the insulation. This analog meter has a fourposition knob to select the test to be made and features a push button to start the test. Megger is a brand name and not a test description although mostly, the equipment being used for this test is branded megger. To accomplish this, a test procedure should be established and used consistently over time. A fourposition switch selects the test to be made system phase sequence, motor rotation and transformer polarity. The goal is to determine if the insulation of a wire has been compromised. Threephase dualvoltage motor insulation resistance testing threephase dualvoltage motors are used for most daytoday operations in todays industrial plants. For each system, megger has the product best suited to conducting a comprehensive diagnostic insulation test. Perform this procedure a number of times as most dc motors use a carbon brush and copper commutator to conduct the electrical power to the armature. It is checked by touching the free ends of the leads together while the megger button is pressed on to check for zero. Jun 22, 2018 but the megger provides a much higher voltage rather than the ohm meters typical threevolt test voltage derived from an internal battery.

A protocol involving voltage level, time duration, intervals between tests and connection methods must be composed, taking into account the type and size of the equipment, its value and role in the production process and other factors. Place one megger probe to the any mounting bolt on the breaker box to test for grounding continuity, then touch the other probe to a motor terminal. First we will disconnect all the line and neutral terminals of the transformer. Oct 19, 2015 how to meg a motor with a megohmeter checking motor condition. Curve b shows same values corrected to 20c see page 22, giving a definite downward trend toward an unsafe condition. Any voltage larger than this may stress the cable and cause premature failure. The megger insulation tester is essentially a highrange resistance meter ohmmeter with a builtin directcurrent generator.

Figure 3typical scale on the megger insulation tester. The generator can be handcranked or lineoperated to develop a high dc voltage which causes a small current through and over surfaces of the insulation being tested fig. These motors run conveyor belts, pumps, fans, and many other applications. Jul 06, 2016 the test generally applies between 100 and 5,000 v or more. Electrical test equipment application solutions from megger. How to megger a motor also known as an insulation test. For three phase motors, connection type is either star y or delta ac motor winding continuity test using a multimeter, check the continuity of motor winding from phase to phase u to v, v to w, w to u. Electricians motor and generator testing equipment megger.

The three lines leading to the right of the test set are for direct attachment to energized ac power systems up to 600 volts to determine the system phase sequence. The test is generally conducted by applying between 100 and 5,000 v or more. Megger testing procedures ieee electrical code issues. Rotate the end shaft approximately 30 degrees and test the motor again. Delivered in onsite case with 1 operating manual, 2 elbowedstraight pvc leads 1. Test interphase resistance by disconnecting the leads from each terminal. Ieee std 1122004, ieee standard test procedure for polyphase. The megger 560000 series motor and phase rotation tester is used to determine system phase sequence, motor rotation, and transformer polarity in electrical systems and motor installations. The test voltage is the rated voltage of the cable the linetoline voltage. Meggers motor and generator testers ensure the correct phase connection in one of our easytouse testers. A catalogue, for quick reference, of the range of megger test instruments for the maintenance of electrical power systems. Megger guide to electrical insulation testing pdf instrumart.

Megger mct1605 test is a lightweight, portable unit for shop and field testing of current transformers using ieee c57. Each phase to phase must have a continuity if winding is ok. The correct settings, connection procedures, test durations and safety precautions must be implemented to avoid damaging the equipment or possible electrocutions. The motor and phase rotation tester permits the electrical contractor or industrial maintenance electrician to permanently connect and tape the terminals of the motor being installed, without having to first energize the motor by a temporary hookup from a power source, if available, to determine motor rotation. Weve assembled helpful technical guides on insulation testing from leading manufacturers in the field.

How to use a megger to measure and test motor insulation. If any particular phase fails the continuity test, your motor is probably burnt. In this video you will find out how to test 3phase induction motor. You do this by using a high voltage and looking for voltage leaking through the insulation.

Insulation resistance testing of low voltage cables in the. Megger leads are connected to lv and hv bushing studs to measure insulation resistance ir value in between the lv and hv windings. This is an insulation test of motor windings, commonly referred to as megging, to megger, or to meg a motor. Insulation resistance testing guide chauvin arnoux. The test measures the insulation resistance between the phases andor between phase and ground. In using the megger, a bit of a learning curve is involved. Battery testing guide 5 battery types there are several main types of battery technologies with subtypes. The leads used for connecting megger testing with the circuit should be fault free and the two connecting leads should have electrical continuity. Megger working principle types history uses of megger. Some units may also incorporate a hand generator to. It should always be kept in mind that, technically, this test should always be addresses or called insulation test. Operators must compose a protocol involving voltage level, time duration, intervals between tests and. What are the possible results of a the megger test.

Hi, ive been asked to find an ieee or equivalent test procedure for meggering from the tleads in an mcc cubicle to the motor in the field. Close to 400 predefined test forms are provided in powerdb covering many types of electrical apparatus such as bushings, batteries, cables, generators, transformers, relays and motors. One of the reasons that it is still such a popular option is because it is nondestructive. As the voltage increases in external circuit the deflection of pointer increases and deflection.

Jul 17, 2017 release the push button on the megger or stop the cranking of the meter. Megger testing of residential circuits inspectionnews. This procedure provides the minimum guidelines and acceptance criteria necessary to ensure that you perform meggering safely and consistently. Megger makes electrical test equipment to help you install, improve efficiency and extend the life of electrical assets and cable networks at high, medium and. Insulation resistance testing is a nondestructive test procedure. The megger is capable of applying different voltages, and the level should be coordinated with the type of equipment under test and the scope of the inquiry. It is an insulation test to see is the insulation has been injured in any way to cause a short circuit when normal power is applied to it. Insulation testing technical guides megger insulation.